Abstract

An uninsulated basement can contribute a significant fraction of a building’s total heating load: insulating the basement can provide significant energy savings. In addition, the desire of homeowners to maximise usable space has resulted in the finishing of many basements. However, traditional interior basement wall insulation assemblies and finishes have resulted in a large number of moisture-related failures of these wall systems, including mould, decay, and poor thermal performance. This thesis involves the experimental and analytical investigation of the hygrothermal behaviour of interior insulated basement walls. The experimental portion involved the hygrothermal monitoring of twelve interior basement insulation assemblies in two field locations (Huntley, IL, and Kitchener, ON). The measured boundary conditions from field monitoring were then used in one-dimensional hygrothermal simulations. None of the monitored walls experienced conditions that would be considered a moisture-related failure; the data demonstrated that the concrete basement wall will be a source of moisture throughout the year. Another conclusion was that air leakage plays a large role in the behaviour of assemblies: performance could not be predicted simply by the permeability of the assembly, or its least permeable layer. Wintertime condensation was not found to be a problem in the monitored walls, with or without an interior vapour control layer. Measurements demonstrated summertime inward vapour drives at the above-grade portions of the walls; condensation was seen in walls with an interior polyethylene vapour barrier, and correlated to an inward thermal gradient. Simulations showed that this issue is likely in climates with a significant cooling load; therefore, locations with negligible cooling loads are unlikely to have these problems. This research suggests that vapour control at the lower portion of the basement wall is unnecessary. These locations experience temperatures that are similar to geographic locations that require no vapour control layer. The monitored data shows that an impermeable layer at this location reduces drying.

Categories

, , , , , ,

Files

File
Hygrothermal Behavior of Interior Basement Insulation

Login is required to access this file

Additional information

  • [acf_PublicationInformation_knowl_meta_originating_url] Orginating URL
  • [acf_PublicationInformation_knowl_meta_year_of_publication] Year of publication
  • [acf_PublicationInformation_knowl_meta_document_type] Document accessibility
  • [acf_PublicationInformation_knowl_meta_publishing_region] Relevant region
  • Version
  • 319 Times downloaded
  • 14.41 MB File Size
  • 1 File Count
  • 8 March 2014 Creation Date
  • 25 September 2019 Last Updated