Abstract

The relative humidity (RH) and the dewpoint temperature (td) are two widely used indicators of the amount of moisture in air. The exact conversion from RH to td, as well as highly accurate approximations, are too complex to be done easily without the help of a calculator or computer. However, there is a very simple rule of thumb that can be very useful for approximating the conversion for moist air (RH > 50%), which does not appear to be widely known by the meteorological community: td decreases by about 1°C for every 5% decrease in RH (starting at td = t, the dry bulb temperature, when RH = 100%). This article examines the mathematical basis and accuracy of this and other relationships between the dewpoint and relative humidity. Several useful applications of the simple conversion are presented, in particular the computation of the cumulus cloud-base level (or lifting condensation level) as zLCL ≈ (20 + t/5) (100 − RH), where zLCL is in meters when t is in degrees Celcius and RH in percent.

Categories

, ,

Files

File
The Relationship between Relative Humidity and the Dewpoint Temperature in Moist Air

Login is required to access this file

Additional information

  • [acf_PublicationInformation_knowl_meta_originating_url] Orginating URL
  • [acf_PublicationInformation_knowl_meta_year_of_publication] Year of publication
  • [acf_PublicationInformation_knowl_meta_document_type] Document accessibility
  • [acf_PublicationInformation_knowl_meta_publishing_region] Relevant region
  • Version
  • 125 Times downloaded
  • 1.68 MB File Size
  • 1 File Count
  • 8 March 2014 Creation Date
  • 25 September 2019 Last Updated