Eric is a Certified Passive House Consultant, PHI Retrofit Expert and Trainer, AECB CarbonLite Retrofit Graduate & AECB Standards Certifier, Chartered Water and Environmental Manager and Chartered Environmentalist. For most of his career, his ‘day job’ mostly involved water supply & sanitation in low-income countries, during which time he helped to co-found BushProof (https://bushproof-madagascar.com/en/home/), an award-winning business based in Madagascar. But it was after gaining experience through carrying out a deep retrofit on his own house, that he retrained as a Passive House Consultant to help other homeowners do the same. He does this through ColdProof (https://www.coldproof.co.uk) which provides master planning for retrofit projects – this is not only about technical details of PHPP, thermal bridge or WUFI modelling, but also about all the other related joined-up thinking and coordination that needs to happen with other specialists and contractors to get the project to the point of being able to start. Eric is passionate about the need for retrofit in the UK, which has been his motivation for helping to develop both the Coaction Passivhaus Tradesperson course (https://coaction.org.uk/courses/tradesperson) and the Retrofit Delivery course (https://coaction.org.uk/courses/retrofit). Details of services we can provide: PHPP modelling Thermal bridge modelling WUFI modelling Coordination with other specialists (MVHR designers, heating/hot water designers, structural engineers) Training & CPD Mentoring, site visits
Hersey Street
Salford
GB
M6 5GT
Certifier
April 7, 2025
Building design/project management
AECB Building Standard, AECB CarbonLite Retrofit Standard, Airtightness/Air Quality/Ventilation, Building Modelling, Building Services, Domestic Retrofit/New Build, Education/Training/CPD, Energy Efficiency/Energy Performance, Fabric First Approach, Health/Comfort/Wellbeing, Low Energy Buildings, Passivhaus, PHPP/SAP/rdSAP, Retrofit
CarbonLite Graduates
[email protected]
07814788846
https://www.linkedin.com/in/eric-fewster-a903334/
https://www.coldproof.co.uk
Eric Fewster
,I have been specialising in planning deep retrofits since 2013. My work involves site surveys, PHPP modelling, thermal bridge modelling, costing, coordinating with other specialists (moisture, structural, ventilation, heat pump), moisture modelling and project management.
CarbonLite Graduates
[email protected]
07814788846
Nationwide
AECB Retrofit Standard for a 1960s detached bungalow in Wrexham
This was a whole house retrofit done in one go, which was certified to the AECB Carbonlite Retrofit Standard. The final space heating demand according to PHPP was around 30 kWh/m2.yr (representing an 86% reduction from baseline), and the team managed to get a good airtightness result (1.015 ACH). The contractor for the job was Jon Day from Myzsa Group, who was responsible for coordinating most of the work. For the walls, this involved insulating the external walls using EPS which required the rafters to be extended at both the eaves and gables, as well as requiring a reconfiguration of the garage roof and a couple of other external structures so that the insulation could pass behind. The cold loft (insulated at ceiling level) was converted to a warm roof that was insulated over / between / under rafters with wood fibre (for which a structural engineer had recommended strengthening a couple of the purlins), the floor had phenolic added over the existing slab, and new windows and doors were installed (which were set on brackets fixed to the outer leaf to ensure no thermal bridging). Thermal bridge modelling was carried out on all junctions to minimise heat loss and check condensation risk. As always with retrofit, there can be some tricky details to resolve in terms of either insulation or airtightness continuity, and in this case the junction between external wall insulation and the pitched roof was a challenge for both – we have written about the airtightness challenge here and our specific solution on a Linkedin post. A heat pump was installed by Integrated Energy which had an operating COP of 4.4, and the MVHR ventilation system was designed by Luft MVHR.